4-8. OVERVIEW.
This section provides maintenance procedures for the output meter at the organizational
maintenance level.
The maintenance procedures for the output meter are organized into the following groups;
Inspection
Cleaning
Touchup Painting
Replacement Procedures
4-9. INSPECTION.
The only inspection procedures at the organizational maintenance level are the PMCS. The PMCS
must be performed at the interval listed. See chapter 5, section lV for the PMCS procedures.
4-10. CLEANING.
Clean the output meter with a soft Iint-free cloth. lt may be necessary to clean meter glass
using soap and a dampened cloth. The metal parts of the output meter can be cleaned using
trichiorotrifiuoroethane.
Adequate ventilation should be provided while using trichlorotrifluoroethane. Prolonged
breathing of vapor should be avoided. The solvent should not be used near heat or open
flame; the products of decomposition are toxic and irritating. Since trichlorotrifluorwthane
dissolves natural oils, prolonged contact with skin should be avoided. When necessary, use
gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physi-
cian immediately.
CAUTION
Do not clean meter glass with trichlorotrifluoroethane. This can damage the output
meter.
4-10