4-11. TOUCHUP PAINTING.
Remove rust and corrosion from metal surfaces by lightly sanding surfaces with fine sandpaper.
Brush two thin coats of proper paint on bare metal. See TM 43-0139 for cleaning and refinishing
instructions.
4-12. REPLACEMENT PROCEDURES.
The following copy provides replacement procedures for the following:
Impedance control knob on Output Meters TS-585A/U, TS-585B/U, TS-585C/U, and TS-585D/U.
Meter multiplier knob on Output Meters TS-585A/U, TS-585B/U, TS-585C/U, and TS-585D/U.
Rubber bumpers on Output Meter TS-585A/U, TS-585B/U, TS-585C/U, and TS-585D/U.
4-11