TM
11-6625-291-14/TO
33A1-7-23-1
4-13. REPLACEMENT OF IMPEDANCE CONTROL KNOB ON OUTPUT METERS TS-585A/U,
TS-585B/U, TS-585C/U and TS-585D/U.
This task covers:
1. Removal
2. Installation
INITIAL SETUP
Personnel Required
Tools
One operator
Tool Kit, Electronic Equipment
TK-105/G
Equipment Condition
Materials/Parts
Output meter on workbench
Knob
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
Using flat-tip screwdriver, loosen screws.
Output Meter
Impedance control
Remove impedance control knob.
knob (1) and
TS-585A/U
Throw away broken knob.
screws (2)
TS-585B/U
TS-585C/U
TS-585D/U
INSTALLATION
Output Meter
Impedance control
trol shaft. Using flat-tip screwdriver,
TS-585A/U
knob (1) and
tighten screws.
TS-585B/U
screws (2)
Check operation of knob.
TS-585C/U
TS-585D/U
4-12