TM 55-4920-244-14
of insulation. Inspect insulation for signs of over-
tacting accessible terminals and replaced on an as
required basis.
c. Cleaning.
e. Repair.
(1) Replace printed circuit board if
(1) Use a soft brush to remove ac-
any of the following conditions exist:
cumulations of dust and dirt.
(a) Separation of plies in board
(2) Use a cloth dampened with dry
material.
cleaning solvent (item 1, table 1-1 ) to remove
(b) Cracks, over 1/8 inch in
foreign matter.
length, or extending into component mounting
d. Inspection and Testing.
area or extending into a printed conductor path.
(1) Inspect printed circuit board for
(c) Carbonized paths between
cracks, separation, carbonized paths between ele-
components, printed conductors, or mounting
ments, and security of components.
areas.
(2) Inspect for cold solder joints and
(d) More than one printed con-
corrosion at all solder terminals and resistor
ductor cut, damaged, or separated from board.
leads.
(e) Separation of terminals from
(3) Inspect all components for dam-
board.
age, broken leads, or signs of overheating.
(2) Single printed conductors may
be replaced with point to point wiring if termi-
nals at each end of defective printed conductor
all resistors are within tolerance.
will accommodate additional wire. Use No. 20
AWG or larger insulated copper wiring for re-
(5) Inspect attaching cable harness
placement purposes.
on deck assembly for broken wires and condition