TM 11-6625-539-14-3
84. Physical Tests and Inspection
82. Test Equipment and Material
a. Test Equipment and Materials. None re-
The only test equipment and material required
quired.
for testing the TS1836C/U is Voltmeter, Elec-
b. Test Connections and Conditions.
tronic ME30(*)/U and a 100-ohm, 1 percent,
(1) No connections are necessary.
1/2-watt resistor.
(2) Remove the test set chassis from its
case.
8-5. Meter OHMS Position Test
a. Test Equipment and Materials. A 100-ohm,
83. Modification Work Orders
1 percent, 1/2-watt resistor is required.
The performance standards listed in the tests
b. Test Connections and Conditions. No con-
nections are necessary other than those indicated
tion that all modification work orders have been
in c below.
performed. DA Pam 3107 lists current M WO's.
c. Procedure.
Control settings
step
Performance standard
No.
Test equipment
Test procedure
Meter pointer indicates full
1
None
Polarity switch:
Observe the meter
FWD PNP.
scale on the OHMS scale.
Function switch :
OHMS E-B.
Meter indicates 100 ohms
Same as step 1
Place the 100-ohm resistor
2
-- .
+5%
between the E and B jacks
on the front panel. Observe
the meter.
Same as step 1.
Remove the 100-ohm resistor,
Same as step 1
3
None
and observe the meter.
b. Test Connections and Conditions. Connect
8-6. Test Set F.E.T. Position Test
the equipment as instructed below.
a. Test Equipment and Materials. The only test
(*)/u.
c. Procedure.
Control settings
Step
Equipment under test
Test procedure
Performance standard
Teat equipment
No.
ME-30(*)/u
ME30(* ) /U indicates 100 mv
Polarity switch: FWD
Connect ME-30 ( * ) /U
1
Range selector
PNP.
_5%.
+
switch: 0 . 3
a c r o s s E and B jacks
Function switch:
Observe the indication on the
F. E. T. CAL.
ME30(*)/U meter.
U.S. GOVERNMENT PRINTING OFFICE: 1977-765-096/459
Change 2