TM 11-6625-291-14/TO 33A1-7-23-1
6-14. REPLACEMENT OF METER MULTIPLIER TERMINAL BOARD.
This task covers:
1. Removal
2. Installation
INITIAL SETUP
Personnel Required
Tools
One technician
Tool Kit, Electronic Equipment
TK-105/G
Equipment Condition
Materials/Parts
Output meter on workbench
Terminal board
See TM 11-6625-291-24P
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
NOTE
board. When removing radial resistors, do not remove jumper
wires.
Leads (1)
1 . Chassis
Using 5/16-inch wrench, remove.
Nuts (2)
2.
Using flat-tip screwdriver and 1/4-inch wrench,
Screws (3) and
3.
remove.
nuts (4)
Lift off.
Terminal board (5)
4.
INSTALLATION
Put in place.
Terminal board (5)
1 . Chassis
Using flat-tip screwdriver and 1/4-inch
Nuts (4) and
2.
wrench, install.
screws (3)
6-22