TM 11-6625-291-14/TO 33A1-7-23-1
2-11. MEASUREMENT OF OUTPUT POWER USING TS-585B/U, TS-585C/U, OR TS-585D/U. (CONT)
ACTION
REMARKS
ITEM
LOCATION
MEASUREMENT (CONT)
Set meter multiplier knob to 100.
Meter multiplier knob
3.. Output Meter
(4)
TS-585BNJ,
Set equipment under test ON.
TS-585C/U, or
TS-585D/U
Set meter multiplier knob to setting where
4.
Meter multiplier knob
(4)
meter reading is slightly to right of center
scale.
More accurate readings are taken when
meter needle points near center of
scale.
NOTE
Read the power in milliwatts by: meter multiplier setting
times the meter reading. Read the power in decibels by:
meter multiplier setting plus the meter reading.
2-19