TM 11-6625-524-14-2
GENERAL
SUPPORT
TESTING
PROCEDURES
7-1. General Testing Procedures
a. Testing Procedures. The testing procedures
Technical manual
Test equipment
are prepared for use by Electronic Field Main-
tenance
Shops and
E l e c t r o n i c Service
T. O. 33A1-8176
Organizations responsible for general support
TM 11-6625-1703-15
maintenance of electronic equipment to determine
the acceptability of repaired equipment. These
TM 11-6625-320-12
Adapter. Millivac So. 900-2100
procedures set forth specific requirements that
Cable Assembly. RF CG-409H
repaired equipment must meet before it is
/U (2 ea)
returned to the using organization.
b. Preliminary Instructions. Follow the in-
s t r u c t i o n s preceding each procedure before
proceeding to the procedure. Perform each step in
a. Test Equipment.
sequence. Do not vary the sequence.
7-2. Test Equipment Required
The test equipment required for general support
(3) On the UUT, turn the LINE switch to
b. Test Connections. Connect the unit under
ON.
test (UUT) to the CN-16B/U which is connected
(4) Connect the ME-30B/U to 3A1TP1 and
to a 115-volt, 60-Hz source.
3A1TP2 on the UUT (3A1TP2 is the negative
c. Procedure.
side).
(1) Turn the range selector switch on the
(5) Adjust 3A1R13 until the ME-30B/U
UUT to the 3 VOLTS range.
reads 14.5-volt dc.
( 2 ) Using the ME-30B/U, measure the
(6) Connect the ME-30B/U from 3A1TP2 to
voltage and adjust the CN-16B/U for a 115-volt
chassis. A reading of - 8.6-volt 5 percent
output .
should be obtained.