Materiel Support Agency, ATTN: SIGMS-PA2d, Fort Monmouth,
N.J.
Test Set, Electron Tube TV2(*)/U (fig. 1) is a portable tube
t e s t e r of the dynamic mutual conductance type. It is used to test
and to measure performance capabilities and to determine rejec-
t i o n limit for electron tubes used in receivers, low-powered trans-
mitters, and other electronic equipment. The following tests can
b e made with the tube tester.
a. S h o r t t e s t .
b. I n t e r e l e m e n t l e a k a g e t e s t .
c. F i l a m e n t c o n t i n u i t y t e s t .
d. Dynamic mutual conductance test for amplifier tubes.
e. Gas test for amplifier tubes.
f. Emission test for vacuum rectifier tubes.
g. Test of gas rectifier tubes.
h. Test of voltage regulator tubes.
i. Plate current tests for triodes.
j. T e s t o f t h y r a t r o n t u b e s .
k. Electron-ray indicator test for electronic indicator tubes.
tube
test.
4. Technical Characteristics
a. Power supply:
Input voltage ________________ 103.5 to 126.5 volts ac.
Frequency------------------------ 50 to 1,000 cps, single-phase.
Power consumption -------------70 watts (no tube under test).
Temperature range ----------- Satisfactory operation from -4 F. to 125 F.
b. Meters:
FILAMENT VOLTS meter:
Type------------------------------ Dc voltmeter movement.
Ac voltage ranges -------------- 0 to 2.5 volts, 0 to 10 volts, 0 to 40 volts, and
0 to 120 volts. Redlines at 0.625, 6.3, 12.6,
and 117 on appropriate scale.
Accuracy -------------------------- 5 percent error at full scale.
GRID BIAS VOLTS meter:
Type ---------------------------------Dc voltmeter.
Sensitivity ---------------- 1,000 ohms per volt.
Dc voltage ranges ---------- 0 to 5 volts, 0 to 10 volts, and 0 to 50 volts.
Accuracy-------------------------- 2 percent error at full scale.