TM 9-4935-282-34
SECTION VI
ACCESSORIES
6-1. PRECISION VOLTAGE DIVIDERS
The Fluke 80A, 80B, and 80C Precision Voltage Dividers
provide the
ability to make high accuracy measurements up to 30,000 volts
DC. All models contain a zero center panel meter which allows
the polarity and approximate magnitude of the unknown high
voltage to be easily observed. At maximum input, all units
draw but 1 ma of current from the unknown. The extreme
accuracy and excellent long term stability of these dividers are
obtained by using properly aged precision wirewound resistors
which have a very low temperature coefficient. To further
ensure high accuracy and long term stability at very high
voltages, the 80C dividers have all resistance components
immersed in oil within a hermetically sealed container. As an
additional feature, all 80B and 80C models are provided with a
1 volt tap which allows measurements of high voltages with a
laboratory potentiometer. Specifications for the standard
models are shown on next page. Other intermediate models
are available upon special request.
6-1