TM 11-6625-539-14-4
Control settings
Step
Performance standard
Test procedures
Test
Equipment
No.
equipment
under test
10
Same.
Repeat steps 8 and 9 and deter-
Power must not exceed 20 milli-
Same.
mine power across C, D and
watts across any jack combi-
E, S remote test jacks. Re-
nation.
peat across C, D and B, G
jacks.
11
Same.
Repeat steps 8 through 10 to
Power must not exceed 20 milli-
Same
except
watts.
RANGE switch:
determine power in all
first X 1.0, then X
ranges across all remote jack
10.
12
Multi meter: AC
FUNCTION switch:
Record voltage across jacks in
Check voltage across C, D and
VOLTS and DC
ICES mode.
B, G remote test jacks, Ad-
I
C
E
S
VOLTS.
POLARITY switch:
just ICES Z E R O / O H M S A D J
PNP or NPN.
controls for maximum volt-
R A N G E switch: X
age.
0.1.
13
ZM-16/U as required.
Use formula in step 2 to deter-
Same.
Connect ZM-16/U across C, D
mine power. Power must not
and B, G remote test jacks.
exceed 20 milliwatts.
age across jacks is one-half
that indicated in step 12.
14
Power must not exceed 20 milli-
Same.
Same
except
Repeat steps 12 and 13 to deter-
RANGE switch:
watts.
mine power across test jacks
first X 1.0, then X
in the two remaining ranges.
10.
15
FUNCTION switch:
Record voltage across jacks in
Check voltage across C, D and
VOLTS and DC
I C E S, IR .
ICO, IR m o d e .
B, G remote test jacks.
VOLTS.
POLARITY switch:
PNP or NPN.
R A N G E switch: X
0.1.
16
Use formula in step 2 to deter-
ZM-16/U as required.
Same.
Connect ZM-16/U across C, D
mine power. Power must not
and B, G remote test jacks.
exceed 20 milliwatts.
age across jacks is one-half
that indicated in step 15.
17
Power must not exceed 20 milli-
Same
except
Repeat steps 15 and 16 to deter-
Same.
RANGE switch:
watts.
mine power across test jacks
first X 1.0, then X
in the two remaining ranges.
10.
18
Record voltage across jacks in
FUNCTION switch:
Check voltage across C, D and
Multi meter: AC
DIODE IN/CKT mode.
VOLTS and DC
B, G remote test jacks.
VOLTS.
POLARITY switch:
PNP or NPN.
R A N G E switch: X
0.1.
19
Use formula in step 2 to deter-
ZM-16/U as required.
Same.
Connect ZM-16/U across C, D
mine power. Power must not
and B, G remote test jacks.
exceed .20 milliwatts.
age across jacks is one-half
that indicated in step 18.
20
Same
Power must not exceed 20 milli-
Repeat steps 18 and 19 to deter-
Same.
except
RANGE switch:
watts.
mine power across test jacks
first X 1.0, then X
in the two remaining ranges.
10.
7-17